USB Digital Meter - USB-A (Type A)
ET900
- 3 to 20V DC; Current: 0.05 to 3A
- Continuously monitor up to 1000 hours of voltage, current, capacity/charge delivered, energy and resistance (calculated)
- Tests most common standard USB-A ports, including Qualcomm Quick Charge® ports
- Store and recall up to 10 readings
- Voltage and current overload detection
- Hi-resolution LCD for clear visibility in environments with low ambient lighting
- Durable cable to allow easy access to hard-to-reach ports
- Rugged, pocket-sized and lightweight Klein industrial design stands up to jobsite demands
- Built to withstand a 6.6' (2 m) drop
- No batteries needed; powered by the USB port that is being tested
The Klein Tools ET900 is a USB digital meter for common standard USB-A (Type A) ports, including Qualcomm Quick Charge® ports. It accurately and reliably measures and displays the USB port voltage, current, capacity, energy and resistance simultaneously. It can function with any USB-A port that has the ability to deliver power. It requires NO batteries as it draws power from the power source to function.
Specifications
Elapsed Time:
Up to 999 Hours, 59 Min, 59 Secs
Current:
0.05 to 3A
Overall Height:
0.56" (1.4 cm)
Overall Width:
1.25" (3.2 cm)
Material:
Polymer
Drop Protection:
2 m (6.6')
Type:
USB-A (Type A)
Ingress Protection:
IP20
Display:
LCD
USB Compatibility:
USB-A; Qualcomm Quick Charge® Compatible
Special Features:
Klein Tools' Most Compact USB Meter
Overall Length:
2.84" (7.2 cm)
Resistance:
400 ohms Maximum
Application:
USB Port Voltage, Current, Capacity, Energy and Resistance (Calculated)
Capacity Used:
99,999mAh Maximum
Weight:
1.10 oz (31.0 g)
Voltage:
3 to 20V DC
Energy Delivered:
999Wh Maximum
Accuracy:
Voltage: 3 to 20V DC +/- 1% (+/-2 Bytes); Current: 0.05 to 3A +/- 1% (+/-2 Bytes)
UPC:
092644691386
Warnings
- To ensure the safe operation and service of this meter, follow all instructions. Failure to observe these warnings can result in severe injury or death.
- This meter will NOT display a current below 50 milliamperes, even if it is allowing this to pass through. NOTE: The display will show zero current.
- Do NOT use with ports that operate outside of the rated voltage and current. NEVER use on a circuit with a voltage or current that exceeds the maximum specified for this device.
- Do NOT use during electrical storms or in wet weather. Do NOT use if the meter appears to be damaged. Use caution when working with voltages above 25 V AC RMS or 24 V DC. Such voltages pose a shock hazard.